BJVGY - TEAM 396 DRAIN OPENER SULFURIC

Product Identification

Product ID:TEAM 396 DRAIN OPENER SULFURIC
MSDS Date:01/01/1987
FSC:7930
NIIN:00F014484
MSDS Number: BJVGY

Responsible Party
TEAM LABORATORY CHEMICAL CORPORATION
323 SOUTH 22ND ST.
BISMARCK, ND 58502

Emergency Phone: (701) 255-3796

Info Phone: (701) 255-3796

Cage: 37912

Contractor
TEAM LABORATORY CHEMICAL CORPORATION
1351 BISMARCK, ND 58502 US

Telephone: (701) 255-3796

Cage: 37912

Ingredients

SULFURIC ACID (SARA III)

CAS: 7664-93-9

RTECS: WS5600000

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRITATION. SKIN: BURNS & RAPID
DESTRUCTION OF TISSUES.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES: IRRITATION. SKIN: BURNS & RAPID
DESTRUCTION OF TISSUES.

First Aid

First Aid:SKIN: FLUSH W/WATER & COVER W/MOIST BAKING SODA. EYES: FLUSH
W/WATER. OBTAIN MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:FOG, DRY POWDER, OR WATER
Unusual Fire/Explosion Hazard:HIGHLY FLAMMABLE & EXPLOSIVE

Accidental Release

Spill Release Procedures:DILUTE W/WATER. NEUTRALIZE W/ SODIUM CARBONATE
OR BICARBONATE.
Neutralizing Agent:SODIUM CARBONATE OR BICARBONATE

Handling

Handling and Storage Precautions:STORE IN COOL, DRY PLACE. MAINTAIN
ADEQUATE VENTILATION. HAVE WATER AVAILABLE. ADD ACID TO WATER -
NEVER ADD WATER TO ACID.
Other Precautions:AVOID INHALATION OF FUMES & CONTACT W/SKIN.

Exposure Controls

Ventilation:PROVIDE ADEQUATE LOCAL EXHAUST VENTILATION.
Protective Gloves:RECOMMENDED
Eye Protection:FULL FACE SHIELD
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:540F
Vapor Pres:0.0090
Vapor Density:3.38
Spec Gravity:1.84
Solubility in Water:100%
Percent Volatiles by Volume:100%

Stability

Stability Indicator/Materials to Avoid:YES
WATER & ACID
Hazardous Decomposition Products:HEAT, STEAM, & EXPLOSIVE HYDROGEN

Disposal

Waste Disposal Methods:FLUSH TO SEWER. HIGHLY FLAMMABLE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.